Accordion M1 Current Source & Supply
Drive and characterise current-driven loads like LEDs — eight software-set currents with per-channel readback, on a networked node.
- 8 independent constant-current outputs, 0–450 mA per channel (max 2.4 A total)
- 16-bit setpoint and 24-bit current readback per channel
- 2 precision measurement inputs, 24-bit, single-ended or differential
- 2-channel programmable power (Mini-PSU), 5–24 V, 1.5 A per channel
- Lifetime licences for Accordion Pilot and Shell included
Accordion M1 Current Source & Supply is a ready-made configuration of the compact M1 platform for driving and monitoring current-driven loads — such as LEDs — in PCBA test, NPI and production test. It combines eight independent constant-current outputs with per-channel current readback, two precision measurement inputs and a 2-channel programmable power module on a networked node. The M1 main board is based on a Raspberry Pi 4; the M.2 slot is free for expansion.
Modules in the configuration
This comes pre-assembled in Accordion M1 Current Source & Supply — click for the datasheet, specifications and connections.
Specifications, connections & manual
All technical material on the page — expand a section, or download the whole datasheet as a PDF.
Specifications
System
| Parameter | Value | Notes |
|---|---|---|
| Product name | Accordion M1 Current Source & Supply | |
| Part number | ESH10000754 | |
| Platform | Accordion M1 (mainboard ESH10000597) | |
| Controller | Raspberry Pi 4, 4 GB | |
| Firmware | Accordion 6.0.0 or later | |
| Power input | USB-C (USB-PD) 20 V, via the bundled 130 W power supply | Use the bundled supply only. |
| Input protection | eFuse, 5 A current limit, overvoltage cut-off above 21 V | |
| Network interface | Ethernet, Wifi | |
| Module slots populated | SO-DIMM (Precision ADC/DAC), N-Top (Current Source), COMTOP (Mini-PSU) | |
| Module slots free | 1× M.2 | |
| Cooling | Active, one fan, speed-regulated by the Accordion process | Full speed at boot. |
| Enclosure | Hammond 1455K1201BU with E# front, top and back panels | |
| Dimensions (L × W × H) | 120 × 78 × 43 mm | |
| Weight | 324 g | |
| Compliance | CE, RoHS, REACH |
Included hardware
| Item | Qty | Notes |
|---|---|---|
| Accordion M1 unit | 1 | Pre-configured with the modules below. |
| ESH10000584 — 8-channel Current Source | 1 | N-Top position. |
| ESH10000590 — Precision ADC/DAC Module | 1 | SO-DIMM slot. |
| ESH10000662 — Mini-PSU | 1 | COMTOP position. |
| microSD card, 32 GB | 1 | Pre-loaded with the Accordion image. |
| USB-C power supply + cable | 1 | 130 W, USB-PD, 1 m cable. |
Lifetime licences for Accordion Shell and Accordion Pilot are included. The Web API, accordionq2 (Python) and AccordionQ2.WebApiClient (.NET) are open clients.
Current outputs (ESH10000584 with ESH10000590)
| Parameter | Value | Notes |
|---|---|---|
| Channels | 8, independently controlled | |
| Output current range | 0–450 mA per channel | |
| Total output current | 2.4 A maximum, continuous, all channels together | |
| Output voltage | 0–5 V | Depends on load and output current. |
| Set-point resolution | 16-bit | |
| Current readback | Per channel, 24-bit ADC | |
| Current sense | 0.5 Ω shunt per channel | |
| Off-state leakage | < 1 µA | |
| Calibration | Two-point (offset + gain) per channel, stored and applied at start-up |
Precision measurement inputs (ESH10000590)
| Parameter | Value | Notes |
|---|---|---|
| Inputs | 2, single-ended or differential | |
| Input range, single-ended | 0–5 V | Scaled ÷2 to the 2.5 V ADC full scale. |
| Resolution | 24-bit | |
| Sensor supply | 5 V, fused at 500 mA | On the measurement connector. |
Power supply — Mini-PSU (ESH10000662)
| Parameter | Value |
|---|---|
| Channels | 2, independent |
| Output voltage | 5–24 V per channel |
| Output current | 1.5 A continuous per channel up to 20 V output; about 30 W per channel above 20 V |
| Current-limit accuracy | ±5 mA after two-point calibration (0–1.5 A) |
| Readback | Output voltage and current per channel |
Manual
Hardware
Power-on: connect the bundled USB-C supply and cable, connect Ethernet, and apply power (starts at power-up or with the power button, as configured). Boot takes about 1 minute. All current outputs and the Mini-PSU outputs are off at boot and must be set and enabled in software.
Connecting loads: one 2-pin push-in connector per current channel (OUT+, GND) — wire the load between OUT+ and GND. The 4-pin measurement connector carries 5 V, GND, MEAS+, MEAS−. The Mini-PSU output connector carries VOUT1, VOUT2, GND. Keep the sum of all channel currents at or below 2.4 A. Power down before changing wiring.
Software
Standard Accordion software — Web API, Pilot, Shell, accordionq2, AccordionQ2.WebApiClient or TestStand (install commands as for the A2 Lite).
- Set each channel’s current, enable it, and read back the measured current.
- Calibration is two-point per channel; run it from Pilot or the API.
- Mini-PSU: set voltage and current limit per channel, then enable.
Pinout
Current outputs (8 × 2-pin, Phoenix Contact 1843606)
| Pin | Signal | Description |
|---|---|---|
| 1 | OUT+ | Current output, positive terminal |
| 2 | GND | Common ground |
Measurement connector (4-pin, Phoenix Contact 1881574)
| Pin | Signal | Description |
|---|---|---|
| 1 | 5V | 5 V supply, fused at 500 mA |
| 2 | GND | Ground |
| 3 | MEAS+ | Single-ended input / differential positive |
| 4 | MEAS− | Single-ended input / differential negative |
Maximum voltage on the measurement pins is 5 V.
Mini-PSU output connector (ESH10000662, 4-pin)
| Pin | Signal |
|---|---|
| 1 | VOUT1 |
| 2 | GND |
| 3 | GND |
| 4 | VOUT2 |