Web UI – Channel Management

The channel page in the Web UI — find, read, set, configure and chart every channel, with live values, statistics, filters and groups.

View as Markdown (for AI/KB)

The Channels page lists every channel in the station, with live values. You use it to find a channel, read its value, set an output, see its statistics and trend, view its details, change its configuration and send it to the chart.

Accessing

In the side menu click Channels, or click a module chip in the status bar to open the page filtered to that module’s channels.

The channel list

Each row is one channel (sorted by alias at first). Columns include On (enabled), Group, Alias, Net name (hidden by default), Type, Dir (IN/OUT/both), Value, Unit, Min/Max/Mean statistics, Trend, Description and Device, plus a ⋮ menu. Rows in italics are system channels — readable but not settable. On a narrow screen the less important columns drop out; on a phone each row becomes a card.

Finding channels

  • Search all columns matches any visible column (and the net name), in any case.
  • Column filters under each title narrow by text or by picking values (Type, Dir, On). Clear filters removes them all.
  • Sort by clicking a title (natural order, so CH2 before CH10).
  • Group by Group, Type, Dir or Device.
  • Columns shows/hides columns; Reset layout returns to defaults.

Live values

The list reads the on-screen channels repeatedly (off-screen channels are not read, keeping it fast). Controls: Pause/Resume, Interval (ms) (100–60000, default 1000; the chart uses the same interval), Clear history and Reload. A status shows what the list is doing (e.g. 24 live · 35 ms, pushed, Paused, Read failed). The list updates by itself when channels are added, removed or reconfigured.

The Value column shows a number (with a light bar for volts on a 0–5 V scale and for percentages), a switch for digital channels (greyed when read-only), N/A for channels with no single value, and … while the first value arrives. Hover to see the exact reported value.

Setting values

You can set a channel whose direction includes OUT and that is not a system channel:

  • Switches (digital) — click the switch, press Space, or use Toggle in the menu.
  • Numbers — click the value (or press Enter), type, press Enter to send (Esc cancels; comma or point both work).
  • Ratiometric — typed in percent (25 → 0.25 on the station).
  • Multiplexers — pick a destination net from a drop-down.
  • Registers / text — typed as text, sent exactly.
  • Several at once — select rows (click, Ctrl/Cmd-click, Shift-click); setting a value applies it to every selected row that takes it. Only rows shown by the filters are changed.

Keyboard

Up/Down move rows, Space toggles the focused switch, Enter opens the editor (and sends in the editor), Esc cancels or clears the selection.

The row menu

Open with ⋮, right-click, or press-and-hold. Items (only those that apply): Read value, Toggle, Show in chart / Remove from chart, Acquire waveform…, Details, Configure…, Select/Deselect, Copy net name, Copy alias.

Details lists everything the station reports about the channel. Configure… changes the channel’s settings (only the fields you change are sent, and a confirmation lists each change). The configurable fields depend on the channel type — for example Analog (gain, offset, input config, default, resolution), Digital (push/pull type, default), UART (baud, bus type, termination byte), SPI (clock, mode, chip-enable high) and I²C (clock speed).

Statistics, trend and memory

Min/Max/Mean are computed from the values read; a new min flashes red and a new max blue. Trend draws the last 50 values. Which columns are shown, the grouping, the sort and the interval are remembered in your browser; filters and the search are not, so a page you open later never hides rows without telling you why.

See also

Book a demo of Probe

Show us your board — we review it and go through the findings together.

Prefer to email? info@esharp.se