Web UI – Power & instruments

A browser front panel for the station's instruments — power supply, PoE, audio, environment and swept numeric measurement.

View as Markdown (for AI/KB)

The instrument pages give you a front panel for the instruments on your station. You can set and switch power-supply outputs, run PoE testers, record and play audio, watch environment meters and capture waveforms with the Numeric page.

Each page is built from the instruments your station’s modules report — you see only the outputs, ports and readings your hardware has. Some pages appear in the menu only when the station has the matching hardware: Power and Numeric are always present, while PoE, Audio and Environment appear when that instrument is fitted. When another client holds the station, controls that change the hardware are disabled or wait until it is free.

Power

The Power page shows one panel for each power-supply output, listed by slot then name. Each panel shows the module/output title, the ON/OFF state and switch, Set voltage and Current limit boxes (with the allowed range shown), measured voltage, current and power (and temperature when reported), and a chart of the last two minutes. A panel shows only the controls the supply has.

To set a value, type it in Set voltage or Current limit and press Enter or click Set (the value is not sent while you type; press Esc to discard; a comma or point both work as decimal separator). A value outside the range is refused. When you turn an output on, a dialog shows the voltage and current limit it will use — confirm with Turn on. All outputs off turns off every output that is on.

PoE

The PoE page shows one panel per PoE tester, with whether PoE power is present, controller readings (input, temperature, total power and current), and per-port sections (power-good/enabled, operating-mode buttons, current/peak/power/class readings and a trend line). Tester actions include Clear peaks, Enable detection, Restart classification, Reset all… and Polarity (you cannot change polarity while a port is powered). The PoE controller starts only when the PoE input is above 42 V.

Audio

The Audio page records and plays sound on the station’s audio devices; files are kept in the media folder. Record by choosing a capture device, length (1–20 s), sample rate, volume (dB) and file name, then Record. Play by choosing a playback device, a file and a volume, then Play. The Recordings and sounds list lets you listen, download, delete and upload .wav files.

Environment

The Environment page shows one panel per environment meter, with temperature, relative humidity, pressure (hPa) and absolute humidity shown large (each with a trend line and recent lowest/highest), and any other readings (dew point, air quality) in a table. A meter measures every 2 seconds by default.

Numeric

The Numeric page acquires a burst of samples from a numeric-result channel and shows it as a waveform, histogram and spectrum, with statistics. Select a Target, set the number of Samples (1 to 100,000, or a preset of 100/1,000/10,000) and click Acquire. Turn on Repeat every to acquire repeatedly, and Keep to retain up to 10 acquisitions on the chart.

Panes: an EMA overlay (smoothed line), a Histogram (2–200 bins) and a Spectrum (FFT) (Hann or no window, optional log frequency/magnitude/dB; the title shows the peak frequency). Drag to zoom (hold Shift or Ctrl to keep an axis; double-click to reset). The Statistics panel shows samples, sample rate, duration, min, max, range, mean, median, σ, RMS, skewness and kurtosis; enter LSL and USL to also see Cp and Cpk. Export the newest acquisition as CSV or the visible panes as PNG.

See also