Originaldokumentationen är på engelska. Visa som Markdown (för AI/KB)
Note: This page describes the chart in the discontinued Windows application Accordion Pilot. The current interface is the browser-based Web UI – Chart Viewer; the concepts below apply to it as well.
Overview
The Chart view provides real-time plotting and historical visualisation for numeric channels — for monitoring trends, analysing signal behaviour and debugging time-dependent issues.
Adding channels
Add a channel from the Channels view (right-click → Add to Chart) or from the Chart view (Add Channel). Each channel is a separate series with its own colour; 5–10 channels per chart is a sensible maximum. Remove a series from the legend.
Configuration
- Lookback points — how many data points to retain. With 500 ms polling, 1000 points ≈ 8 minutes; with 100 ms polling ≈ 2 minutes.
- Y-axis — auto-scales by default; set a manual range to zoom into a band.
- Time axis — relative (−60 s … 0 s) or absolute (time of day).
- Update interval — follows the main polling interval.
- Clear history — removes all points and starts fresh.
Analysis
Hover for a tooltip (time, channel, value) or enable a crosshair to read all series at one time. Zoom with the mouse wheel or by dragging a rectangle; double-click to reset; pan by dragging. A statistics view gives min, max, mean, std dev and sample count for the visible data. A second Y-axis can carry channels with a different scale (e.g. voltage left, current right).
Export
Export the chart data to CSV/Excel (timestamp + one column per series) or save the chart as an image (PNG/JPEG/BMP) for reports.
Timestamp,CHANNEL_1,CHANNEL_2
2024-01-15 14:30:00,3.3,1.5
2024-01-15 14:30:01,3.31,1.52
Performance
Chart load depends on the number of series, the lookback size and the polling rate. Keep to 5–10 channels and a reasonable lookback (1000–5000 points), clear history periodically, and close the chart view when it is not needed.