Power and PDN

Probe's power-related analyses: IR-drop, the power-distribution network (PDN), rail loads and the power cards in the viewer.

View as Markdown (for AI/KB) Whole knowledge base (llms.txt)

The power paths are where many hard-to-find faults live. Probe collects power-related analysis in a few panels that all rest on the as-built copper and the device facts the review has gathered.

IR-drop

The IR-drop analysis shows the voltage drop along the power paths — where the copper is too thin for the current it carries. The result is shown as a map over the board.

PDN and rail loads

The power-distribution network (PDN) describes how each rail is fed and loaded. You state the rail loads and targets, and Probe can reason about whether the distribution holds. The power cards in the viewer summarise rail by rail.

What the material is

The analyses build on physical geometry and therefore require a layout (ODB++) — they belong to the post-layout review, not pre-layout. Values that need device facts (e.g. a regulator’s behaviour) are cited from datasheets.


Related: stackup and copper and signal integrity.

Probe is E-Sharp’s design-review engine. Quantitative checks carry their numbers and their source.

Book a demo of Probe

Show us your board — we review it and go through the findings together.